Calculations
The Peak values report contains data that is calculated. This section explains these calculations.
Measurements are limited to values measured during office hours (in the following examples, the office hours are from 08:00-18:00 = 600 minutes).
Percentage valid readings
Percentage valid readings |
---|
Valid readings / Office hours in minutes | 525 / 600 | *100 | = | 87,5% |
A reading is valid if the measurement point is not in the
Immeasurable status.
Percentage occupied
Percentage occupied (measurement point) |
---|
Number of minutes in status Occupied or Idle / Valid readings in minutes | 350 / 600 | *100 | = | 58,3% |
Percentage reserved
Percentage reserved (measurement point) |
---|
Number of minutes with valid reservations linked to MP / Valid readings in minutes | 485 / 600 | *100 | = | 80,8% |
MP stands for measurement point.
The occupancy and reservation calculations are based on the office hours in minutes. If the result is 50 % this means that the workspace was occupied or reserved during 50% of the office hours.
To ensure valid calculations, only those results are taken into account if the readings cover at least 80% of the available period. This filter is especially meaningful for individual measurement points.