Field | Description |
---|---|
Measurement point | Displays the linked measurement point. |
Type | Displays the summarization type. |
Year | Indicates the year of the summarization period. |
Month | Indicates the month of the summarization period. |
Day | Indicates the day of the summarization period, if applicable. |
Hour | Indicates the hour of the summarization period, if applicable. |
Composed date-time | The value in this field is composed of the preceding four reading field values for Year, Month, Day and Hours. By using this field, it is now possible to create a From-To analysis for a period. Hour summarization Start date-time of hour: Year: 2020 Month: 06 Day: 25 Hour: 14 Composed data-time: 25-06-2020H14.00 Day summarization Start date-time of day: Year: 2020 Month: 06 Day: 25 Composed date-time: 25-06-2020H00.00 Month summarization Start date-time of month Year: 2020 Month: 06 Composed date-time: 01-06-2020H00.00 |
Readings (in min.) during office hours | Displays the number of minutes of valid readings (in the status Non-occupied, Reservation imminent, Occupied or Idle) within the the summarization time frame. |
Time slot | Displays the actual number of minutes in the office calender within the summarization time frame (day/week/month). Example (hour) Office hours = 8:30 - 17:00 For time bucket 8, the time slot will be 30 minutes For time bucket 9-17, it will be 60 minutes each. Calculation % of valid reservations: (mins. of valid reservation / time slot) * 100.0 |
Reserved status (in min.) | Displays the number of minutes in the status Reserved during office hours within the summarization time frame. |
Non-occupied status (in min.) | Displays the number of minutes in the status Non-occupied during office hours, within the summarization time frame. |
Occupied status (in min.) | Displays the number of minutes in the status Occupied during office hours within the summarization time frame. |
Idle status (in min.) | Displays the number of minutes in the status Idle during office hours within the summarization time frame. |
Immeasurable status (in min.) | Displays the number of minutes in the status Immeasurable during office hours within the summarization time frame. |
Minimum occupancy value | Displays the minimum occupancy value during office hours for readings in status Occupied within the summarization time frame. |
Maximum occupancy value | Displays the maximum occupancy value during office hours for readings in the status Occupied within the time frame. |
Valid reservations (in min.) | Displays the number of minutes for which a valid reservation existed for the measurement point during office hours within the summarization time frame. This is based on the value in the Time block field. |
Total occupancy value | Displays the sum of all occupancy values during office hours in the status Occupied within the summarization time frame. The sum is based on the Person count field. Example When measuring 10 minutes occupancy for 8 persons in one hour, the value is 80. |
Max. capacity | Displays the sum of all maximum capacity values during office hours in the status Occupied within the time frame. |
Reserved capacity | Displays the sum of all people for whom a reservation was planned during office hours in the status Occupied within the time frame. |
Number of 'no-show' events | Displays the number of No-show events during office hours. |
Time saving from 'no show' | Displays the net time savings as a result of making a space available by detecting a 'no show'. |
Number of 'early departure' events | Displays the number of Early departure events during office hours. |
Time saving from 'early departure' | Displays the net time savings as a result of making a space available by detecting an 'early departure'. |
Free measurement field 1/10 | Free fields made available for capturing numeric values, e.g. number of particles in a given time frame. This data must be supplied by the sensoring system. Because they are numeric values, they can be summarized and used in analysis. |
Environmental measurements Environmental measurements all display summarized values of valid measurements. | |
Battery status (voltage) | Displays the battery indication (voltage) received from the connector. The value indicates the status of the sensor's power supply. If multiple sensors are linked to the measurement point, the lowest battery voltage is returned. |
Light intensity (lux) | Displays the luminous intensity or lux (lx) received from the connector. |
Carbon dioxide (ppm) | Displays the carbon dioxide level received from the connector. The measurement point's carbon dioxide level is given in parts per million (ppm). |
Humidity (%) | Displays the humidity percentage received from the connector. |
Noise (dB) | Displays the loudness level received from the connector. The measurement point's loudness level is given in decibel (dB). |
Temperature (degrees) | Displays the temperature received from the connector. The measurement point's temperature is given in degrees Celsius or Fahrenheit, which is determined by the sensoring system. |
Power level (kWh) | Displays the power level value received from the connector. The power level indicates the energy usage in kilowatt (kWh). |